Inground technical room Hayward

Delivery fees free **
Price
Consult us
Inground technical room Hayward, details :
Key functions
| Inground technical room is an ideal solution for your swimming pool project. Easy and rapid installation. You have the choice to equip it according to your needs: - Technical room 'empty', to equip according to your needs. - Pre-equipped technical room (with filtration pump, sand filter, plumbing connectors) These quality materials will blend perfectly into your pool environment. Technical rooms dimensions according to models.
| ![]() |
Pump Max Flo
| Pump made from PermaGlass XL. 1"1/2 connector Prefilter basket volume 1000 cm³. Flow from 11 to 14m³/h . It has an extraordinary chemical resistance and corrosion resistance in saline atmosphere. Ceramic carbon gasket. Lexan transparent lid very easy to open and close. Low noise level. Low electricity consumption. | ![]() Max Flo range pump curve |

Pump dimensions Hayward Max Flo in mm ("A" = 213mm)
Filter
| High density polyethylen filter with automatic drain. Maximum pressure : 3,5 bars. Delivered with 6-position Variflo valve. Slotted tip laterals : Folding slotted tip laterals for easy and rapid maintenance. ![]() | ![]() |
| 1. Manual drain plug for purging air. 2. Filter attached with a clamp for easy filter inspection. 3. Integrated diffuser for better water distribution and flow. 4. High performance water collector with self-cleaning slotted tip laterals for better flow and easier backwash. 5. Integrated drain plug to let the water out easily. | 6. Automatic purge. 7. All weather resistant high density anti-corrosion tank, minimum maintenance. 8. Vari-Flo Hayward 6-position valve 9. Anti-corrosion base with great design for better stability. |
Electrical box
Electrical box of the semi-sunk technical room Hayward equipped with 3 functions :
1. Timer
The filtration time can be chosen and preset.
The following table can be used to calculate the necessary filtration time:
| Water temperature | Chlorine Bromine Active oxygen* | PHMB* |
| Up to 10°C | 2h | 2h |
| From 10°C to 12°C | 4h | 4h |
| From 12°C to 16°C | 6h | 7h |
| From 16°C to 24°C | 8h | 12h |
| From 24°C to 27°C | 10h | 14h |
| From 27°C to 30°C | 15h to 20h | 15h to 20h |
| Above | 20h to 24h | 24h |
* Filtration time per day.
Starting from 20°C water temperature, you can also use the following formula :
Temperature/2 = Filtration time per day
If the water turns green, continuous filtering is recommended until the problem is resolved.
2. Protection
The electric box protects the pump with a magnetothermic circuit breaker and electro-magnetic switch. It protects the pump against short-circuits and voltage overload.
3. How to order
The electric box commands the pump and /or 12 volt lamps with the programmed timer.
It is recommended to install an electrical protection with a differential circuit-breaker in front of the electrical box.
| Transformer 300W | (25A) | Transformer 600W | (25A) |
| SECTION | LENGTH | SECTION | LENGTH |
| 4mm² | 2,10m | 10mm² | 2,10m |
| 6mm² | 3,20m | 16mm² | 3,20m |
| 10mm² | 5,30m | 25mm² | 5,30m |
| 16mm² | 8,50m | 35mm² | 8,50m |
| 25mm² | 13,50m | 50mm² | 13,50m |
| 35mm² | 18,60m | - | - |
Table of the absorbed power per engine/circuit-breaker size.
Indicative table of the absorbed power for single-phase engines.
| Circuit-breaker size | Absorbed intensity | hp | kW |
| 1,6 / 2,4 | 2,2 A | 1/3 | 0,25 |
| 2,4 / 4 | 3,12 A | 1/2 | 0,37 |
| 4 / 6,3 | 4,76 A | 3/4 | 0,55 |
| 6,3 / 10 | 6,01 A | 1 | 0,75 |
| 6,3 / 10 | 7,60 A | 1 1/2 | 1,10 |
| 10 / 16 | 10,40 A | 2 | 1,50 |
Absorbed intensity diagram for three-phase engine
| Circuit-breaker size | Absorbed intensity | hp | kW |
| 1 / 1,6 | 1,03 A | 1/3 | 0,25 |
| 1,6 / 2,4 | 1,60 A | 1/2 | 0,37 |
| 1,6 / 2,4 | 2 A | 3/4 | 0,55 |
| 2,4 / 4 | 2,60 A | 1 | 0,75 |
| 2,4 / 4 | 3,50 A | 1 1/2 | 1,10 |
| 4 / 6,3 | 5 A | 2 | 1,50 |
| 6,3 / 10 | 5 A | 3 | 2,20 |
| 6,3 / 10 | 6,60 | - | 3,60 |
Actual products may vary from images shown
Prix TTC.
Ask for a free quote Inground technical room Hayward
Please fill in this form carefully. Our commercial service will handle your request promptly.